FOR IMPORTERS, DISTRIBUTORS & RETAIL PROGRAMSSales Department · (+84) 868 848 620
SJOOW
Flexible cord

SJOOW

Junior-service flexible portable cord with oil-resistant layers.

United StatesCanada
Sizes, construction & electrical data
SJOOW / TECHNICAL DATA

Sizes, construction & electrical data

Dimensional and electrical reference · Copper · 300 V

Conductor material
Copper (Cu)
Insulation material
EPDM
Rated voltage
300 V
Maximum conductor temperature
90°C
Jacket / armour
CPE
Ampacity basis
2023 NEC 400.5(A)(1) / CEC Table 12; current-carrying conductor count applies
Dimensional and electrical reference · Copper · 300 V
ConfigurationNominal area / conductormm²Conductor sizeAWG / kcmilInsulated conductorsStrands per conductorInsulation wallmmOuter jacket wallmmOverall dimensions / diametermmApproximate cable weightkg/kmReference cord ampacityASelection
18/20.823182410.7621.0167.36665.510
18/20.823182160.7621.0167.31575.910
18/30.823183160.7621.0167.87487.87
18/40.823184160.7621.0168.458108.65
16/21.309162260.7621.0167.9584.813
16/21.309162650.7620.7628.25598.213
16/31.309163260.7621.0168.433107.110
16/41.309164260.7620.8899.144129.58
14/22.081142410.7620.8898.534102.718
14/32.081143410.7621.0169.169138.415
14/42.081144410.7621.01610.1618312
12/23.309122650.7621.52410.541162.225
12/33.309123650.7621.52411.024215.820
12/43.309124650.7621.2711.862260.416
10/25.2611021041.1431.77814.097258.930
10/35.2611031041.1431.90514.453348.225
10/45.2611041041.1431.77816.25643920

Typical applications

Portable appliances, tools and suitable extension assemblies.

Design advantages

Flexible construction for lower-voltage portable equipment.

Selection notes

300 V SJOOW is not interchangeable with 600 V SOOW. Ratings vary by compound.

Standards to review

UL 62; CSA C22.2 No. 49; NFPA 70 §400

Related cable families

TGS · VIETNAM

Let’s connect your next project.

Send your cable type, destination market and volume. We will review the next steps with you.

Request a quote